SQL Server 2022 with APPX 5.5.4 on Rocky Linux
Set up SQL Server as an APPX file system using FMS type 6. Start with one file, then save a record in APPX and check it in SQL Server.
APPX 5.5.4 · 32-bit engine SQL Server 2022 · FreeTDSWhat to install
The example uses a 32-bit APPX 5.5.4 engine on Rocky Linux 9.8 and a 64-bit SQL Server 2022 (16.0.4305.5) database. Install the 32-bit FreeTDS client on the APPX server.
| Component | Download |
|---|---|
| APPX server | Install the 32-bit APPX 5.5.4 engine. On x86-64 Rocky Linux, use the installer for 64-bit Linux. It installs the 32-bit APPX engine. APPX 5.5.4 Linux server installer · Installation instructions |
| APPX Desktop Client | Use the 5.5.4 Desktop Client to open an APPX session. Desktop Client installer |
| SQL Server | Install SQL Server 2022 or use an existing server with a dedicated test database. Database installation |
| ODBC driver | Match the client to the APPX engine’s 32-bit architecture. FreeTDS 1.5.21 |
Install unixODBC.i686. The lab used unixODBC 2.3.12 and a matching 32-bit isql under /usr/local/unixodbc32.
Build FreeTDS 1.5.21 with the 32-bit unixODBC headers and GnuTLS. Install the 32-bit GnuTLS, libgcrypt, and libtasn1 development packages on the build machine. The lab used GnuTLS 3.8.10. Download the FreeTDS schema statement patch and run these commands from the unpacked FreeTDS source directory.
patch -p1 < /path/to/freetds-1.5.21-appx-ddl.patch
CC='gcc -m32' GNUTLS_LIBS='-lgnutls -lgcrypt -ltasn1' \
./configure --prefix=/opt/freetds32 --with-unixodbc=/usr/local/unixodbc32 \
--with-gnutls --without-openssl
make
sudo make install
file /opt/freetds32/lib/libtdsodbc.so
/opt/freetds32/bin/tsql -C
Memory corruption detected (FP.C.8322). If this occurs while APPX opens FreeTDS, check that your driver is the 32-bit GnuTLS build and that the APPX DSN points to it. The crash was reproduced during OpenSSL initialization.
Check the APPX/ODBC product registration for SQL Server. If the APPX error names ODB, check the registration before troubleshooting the DSN.
Choose a database and create a login
Ask your DBA for the host, port, and database name. This single-byte example uses appxsb with SQL_Latin1_General_CP1_CI_AS. Use a dedicated schema or database to rehearse the setup. Replace the example password with a generated value.
CREATE DATABASE appxsb COLLATE SQL_Latin1_General_CP1_CI_AS;
GO
CREATE LOGIN appx_sql_demo WITH PASSWORD = N'use_your_test_password',
DEFAULT_DATABASE = appxsb;
GO
USE appxsb;
CREATE USER appx_sql_demo FOR LOGIN appx_sql_demo WITH DEFAULT_SCHEMA = dbo;
GRANT CREATE TABLE TO appx_sql_demo;
GRANT ALTER, SELECT, INSERT, UPDATE, DELETE ON SCHEMA::dbo TO appx_sql_demo;
GO
Confirm that the SQL login can open the selected database. If the driver reports Cannot open database requested by the login, check the DSN database and the user mapping in that database.
Set up the 32-bit System DSN
Register the 32-bit driver in odbcinst.ini and create the System DSN in odbc.ini. Run odbcinst -j to find these files. Point the engine’s appx.env to the same directory and 32-bit driver manager.
# odbcinst.ini
[FreeTDS]
Driver=/opt/freetds32/lib/libtdsodbc.so
# odbc.ini
[APPX-SQLSERVER]
Driver=FreeTDS
Server=127.0.0.1
Port=1433
Database=appxsb
TDS_Version=7.4
Encryption=require
ClientCharset=CP1252
MARS_Connection=Yes
APPX_ODBC_LIB=/usr/lib/libodbc.so.2
ODBCSYSINI=/etc
Test as the APPX engine’s account using the same DSN directory and the 32-bit isql. Enter the password at the prompt.
read -rsp 'Test password: ' test_password; printf '\n'
ODBCSYSINI=/etc /usr/local/unixodbc32/bin/isql -v APPX-SQLSERVER appx_sql_demo "$test_password"
unset test_password
Invalid cursor state (SQLSTATE 24000). If a record save fails with this error, check that MARS_Connection=Yes is in the System DSN used by APPX. Open a fresh APPX session after saving the setting.
Set up the FMS group and identity
Open a new APPX Desktop Client session. Choose System Administration → Configuration → File System Groups under File Maintenance.
- Add
APPX-SQLSERVERand enter FMS type6. - Click FMS Group Attributes. Enter the values below and save.
| FMS option | Value |
|---|---|
| Data Source Name | APPX-SQLSERVER |
| Table Naming Scheme | APPX_$db_$appl_$file |
| Proxy Database ID | LOK |
On the group row, click Identities. Enter your APPX user ID to give that user a database login. Leave APPX User blank to set a default identity for the group. Press Enter to accept the key and again to open the details.
Enter appx_sql_demo in User Id and leave Realm blank. Save the identity and reopen it in Change mode. Click Change Password, enter the database password, and press Tab to move to Confirm Password. Enter it again and click Change Password. When APPX reports Password Changed, END to Exit, close the password dialog and save the identity. Open a fresh APPX session before testing.
Assign one file and create the table
Use a test database and a file you can create empty. This example uses the Demo Application’s COUNTRY file.
- Open System Administration → Database/Applications → Databases / Applications under File Maintenance. Add
TSTwith the company name SQL Server Test. Set the startup application toDMO, version00. Save and accept the report defaults. - For
TST, open Related Applications. AddDMOin Live Operations if it is absent. Select theDMOrow and click Database Management. If APPX prompts for a Language ID, setENGand reopen Database Management. - In File Selection, click Unselect All. Highlight
COUNTRYand press F3. If you use the Select button, enterCOUNTRYin Name and confirm. Return to Data File Management and confirm that one file is selected. - Open File Specifications. Set FMS to
6and FMS Group toAPPX-SQLSERVERforCOUNTRY. Save and return. - Choose Create Files. The result for
COUNTRYshould say Created.
No More Records during Create Files. Confirm that the installed FreeTDS driver was rebuilt with the schema statement patch and that APPX is using that driver. In the lab, the original driver returned SQL_NO_DATA after CREATE TABLE and the table rolled back when APPX closed.
This naming scheme creates dbo.APPX_TST_DMO_COUNTRY in the selected database or schema. For an existing file, follow the APPX/IO migration and rollback guide.
Save and check a record
- From the APPX main menu, choose Run an Application and execute database
TST. In the demo’s top menu, choose Setup → Countries. - In Country Address Format Rules, choose Add. Enter
CANADAfor Country Name,PROVINCEfor Region Label, and2for # Words In Postal Code. Leave Postal Code Location at AFTER REGION. Click Save. - Repeat with
ENCODINGfor Country Name,Québecfor Region Label, and1for # Words In Postal Code. Save. - Open a fresh Desktop Client session, run
TST, and go back to Setup → Countries. Choose Inquire and click First Record if the key field is empty. Find the two keys and confirm the saved values, including the accent inQuébec.
Cannot Access Required File for PROSPECT. In a test database with only COUNTRY created, click Cancel on this message to continue the Countries test. Create the full demo database to run the rest of the application.
Connect independently in sqlcmd as appx_sql_demo. Check the records, encoded value, and unique index on country_name.
SELECT RTRIM(country_name), RTRIM(country_region_label), country_no_words,
CONVERT(varbinary(30), RTRIM(country_region_label)) AS stored_bytes
FROM dbo.APPX_TST_DMO_COUNTRY ORDER BY country_name;
EXEC sp_helpindex N'dbo.APPX_TST_DMO_COUNTRY';
GO
Expect CANADA / PROVINCE / 2 and ENCODING / Québec / 1. In the Windows-1252 text, é is byte E9.
Troubleshooting
Check the APPX engine
This guide uses FMS type 6 (ODBC) through the SQL Server ODBC driver.
In APPX Release Information, record Engine Release and Compile Date. The application release numbers on the same screen identify the APPX system applications. Match the database client or ODBC driver to the bitness of the engine that runs the operation. Check the settings on the APPX server and under the Windows or Linux account that runs the engine.
Test the connection outside APPX
On the APPX server, use the 32-bit isql and the DSN from FMS Group Attributes. Check the driver, server, port, and database. Use the same login and password as APPX. Run odbcinst -j from the matching unixODBC installation to see its configuration paths. Check ODBCSYSINI and ODBCINI in the engine’s environment. If the driver fails to load, check its bitness with file and its dependencies with ldd.
For a timeout or connection refusal, check the database service, listening address and port, and firewall. A database authentication error means the request reached the server. Check the matching server log entry for the reason it rejected the login.
For a TLS error, check the certificate name and the Linux host’s trusted certificates. For a SQL login error, check the account and /var/opt/mssql/log/errorlog. Confirm that APPX_ODBC_LIB points to the 32-bit unixODBC library.
Check the FMS group and Identity
If APPX reports Can’t connect to server (or driver error) after a successful DSN test, confirm that the FMS group’s Data Source Name matches the tested System DSN. The DSN test uses the credentials supplied to the test. APPX uses the credentials from its FMS Identity.
Under Identities, look for an active, unexpired entry for the APPX user running the operation. That entry takes precedence over the blank default. Check User Id and re-enter the database password with Change Password. Save the Identity and open a fresh APPX session. APPX can cache connection and Identity settings for the life of the session.
If the same password works in the DSN test and fails in APPX, check the driver’s connection string rules and the password length supported by the APPX release. A dedicated test login with a newly generated alphanumeric password can help isolate a parsing or length problem.
Check where APPX creates the table
If the connection succeeds, read the Create Files result or open View Log for the database error. Check the database, login, and target schema or database with the same connection settings as APPX. Compare the APPX database ID, application ID, file name, and Table Naming Scheme with the SQL table name.
Check the DSN’s database and the database user’s default schema. The database user needs CREATE TABLE in the database and ALTER on the target schema. SQL Server table creation permissions
For an APPX error that names the ODB license, check the APPX/ODBC registration on the engine that opened the file. A driver connection test does not exercise the APPX registration check.
Capture one failing operation
Make a copy of the
appx.envunder the effectiveAPPXPATHof the engine that runs the process. Create a private log directory that the engine account can write to, then temporarily set the variables below. Keep$(pid)as written. The SQL logger replaces it with the engine process ID.APPX_SQL_CMD=/var/tmp/appx-trace/appx-rdbms-$(pid).log APPX_DBG_CODE=0x201FThe mask includes generated SQL, return statuses, fetch attempts, and engine and connection operations, plus proxy lock operations where applicable. Use
0xFFFFFFFFfor one attempt if support needs more detail. The engine reads these settings on startup.APPX_ODBC_LOGandAPPX_ODBC_CODEapply to the driver used by external programs to read APPX data.- If the APPX SQL log lacks the driver error, add
Trace=YesandTraceFile=/var/tmp/appx-trace/odbc.logunder[ODBC]in the engine’sodbcinst.ini. This can trace other applications using that configuration. Limit the capture to one attempt. unixODBC tracing settings - Open a fresh APPX session and reproduce the failure once. For Create Files, select only the intended test file. For a failed
READwithHOLD, note the APPX error and flags before the nextWRITE. Try a plainREADof the same key in another fresh session. If the log is missing, checkAPPXPATH, the effective variables, and the engine account’s access to the log directory. - Exit the test sessions and restore the previous
appx.envsettings. If you enabled unixODBC tracing, restore the previousodbcinst.inisettings.
If an insert follows a failed held read, keep the first error. A later duplicate-key error indicates that the key existed when the insert ran. Use the insert branch only when the read explicitly reports that the record was absent. Handle lock and database errors before trying another write.
In the ODBC trace, find the first failed call and its diagnostic records. For SQLDriverConnect (which may appear as SQLDriverConnectW), capture the return code, SQLSTATE, and full driver message. IM002 points to DSN or driver lookup. 08001 covers several connection failures, so read the message that accompanies it.
Share the SQL statement, fetch or lock result, and the first SQLSTATE, native error number, and message when available. Include the APPX flags, file and operation, timestamp and time zone, APPX engine release, build date and bitness, operating system, driver name and version, and database versions before and after an upgrade. Keep the SQL structure and error codes intact and replace passwords and record values with placeholders. The APPX SQL log can contain the engine environment and full connection strings. APPX environment settings
If the SQL query returns a different result from the APPX screen, verify the effective FMS group, database, schema, and table name. Restart the APPX session after changing any of them.