APPX Software Library

Chapter 4-2: True/False Status Indicators

Valid/Invalid Execution Conditions

The following are examples of valid and invalid true/false execution conditions as specified in the first five positions of a statement. The next level referred to below identifies the internal true/false status indicator to be set assuming the statement affects these indicators (as identified in Table 4-2-1).

Valid T/F Execution Conditions

• • • • •No execution conditions apply; next level is level 1.
T • • • •One condition applies; next level is level 2.
T T F T •Four conditions apply; next level is level 5.
F F F T TFive conditions apply; next level is invalid.*

* Note: Five conditions are not valid on a statement affecting the internal T/F status indicators (except for GOSUB and RETURN).

Invalid T/F Execution Conditions

• T • • •A non-blank execution condition cannot follow a blank.
T F • • TA non-blank execution condition cannot follow a blank.